Panic Door Hardware Requirements

The actuating portion of the panic device must be at least half the width of the door.
Panic door hardware requirements. Panic hardware used on balanced doors must be touchpad type and the touchpad must not extend more than half the width of the door measured from the latch side. The panic hardware requirements vary depending upon the year and other factors. Above all equip doors with panic hardware and fire exit hardware. 2006 and 2009 ibc requires panic hardware on egress doors in educational and other buildings with 50 or more occupants.
Where panic hardware is required the actuating portion of the device touchpad or crossbar must be at least half the width of the door leaf. The actuating portion of the panic device must measure at least half the width of the door example. Hardware consisting of bars that extend to at least half of the width of the door leaf. Other requirements for panic hardware include.
Current codes require panic hardware to be mounted. The maximum unlatching force shall not exceed 15 pounds. A 3 2 door requires the touchpad or crossbar to be at least 19 long. An applied force of 15 pounds should be enough to release the latch.
2000 and 2003 ibc requires panic hardware on egress doors in educational and other buildings with 100 or more occupants. For example this should not be less than 30 inches and not more than 44 inches above the floor.